Concox AT4

Concox AT4
Manufacturer: Jimi IoT (Concox)
Forum Discussion

Number of units

2244
Online
5669
Total
Features Concox AT4:
  • Wi-Fi positioning
Supported in Wialon:
  • Remote management via GPRS
  • LBS
  • Remote management via SMS
  • Communication via TCP

The following data should also be added to Concox AT4 unit properties section of Wialon GPS tracking software :

Device type: Concox AT4
Unique ID: imei

Specify the following parameters in configuration software or configuration Concox AT4 for use in Wialon Hosting :

Server port: 21472

5669 units of Concox AT4 device type are connected to Wialon Data Center. This represents 3.48% of all Asset trackers connected.

Below chart represents the dynamic of connections in the last 30 days:

Parameter name Description Units
voltage Voltage level
gsm

GSM Signal Strength:

  • 0x00: no signal;
  • 0x01: extremely weak signal;
  • 0x02: weak signal;
  • 0x03: good signal;
  • 0x04: strong signal.

serial Serial number of data sent
mcc Mobile Country Code
mnc Mobile Network Code
lac Location Area Code
cell_id Cell Tower ID
acc ACC Status. ACC low: 00, ACC high: 01
data_mode

GPS data upload mode

  • 0x00 Upload by time interval
  • 0x01 Upload by distance interval
  • 0x02 Inflection point upload
  • 0x03 ACC status upload
  • 0x04 Re-upload the last GPS point when back to static.
  • 0x05 Upload the last effective point when network recovers.

gps_real_up 0x00 Real time upload 0x01 Re-upload
rssi

Signal level of community,range 0x00~0xFF,

  • 0x00 Weakest signal
  • 0xFF Strongest signal

tmng_adv Value= “Actual time of signal from Mobile Station to Location base”-“Time of signal from Mobile Station to Location base supposed the distance is 0”
voltage_lvl

Voltage Level:

  • 0x00:No Power (shutdown)
  • 0x01:Extremely Low Battery (not enough for calling or sending text messages, etc.)
  • 0x02:Very Low Battery (Low Battery Alarm)
  • 0x03:Low Battery (can be used normally)
  • 0x04:Medium
  • 0x05:High
  • 0x06:Very High

alarm_state

Alarm information:
0:normal
1:SOS
2:Power cut alarm
3: Vibration alarm
4:Enter fence alarm
5:Exit fence alarm
6 Over speed alarm
9 Displacement alarm
10:Enter GPS dead zone alarm
11:Exit GPS dead zone alarm
12: Power on alarm
13: GPS First fix notice
14: Low battery alarm
15: Low battery protection alarm
16: SIM change notice
17: Power off alarm
18: Airplane mode alarm
19: Disassemble alarm
20: Door alarm
21: Low battery and shutdown alarm
22: Sound control alarm
23: Pseudo base-station alarm
24: Open cover alarm
25: Internal low Battery Alarm
32: Sleep mode Alarm
34: Insert charger alarm
40: Offline pre- alarm
50: Pull alarm